Summary for Test 2023-12-05-62-1

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 215425
DEA: 06360244
EFIS: 0613000005
DIST-CO-RTE-PM06-TUL-99-30.6/35.2
Award Date04/23/2021
Closeout DateNot set
Work DescriptionWiden Freeway & Bridge Construction (Concrete Bridge)
Location DescriptionNot set
QA Service Level1 (Verified on 11/01/2021)

Sample Information

Sample Taken Date12/05/2023 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/06/2023
Sample typeDepartment Acceptance A brief description of the sampleCIDH Pile
The quantity of what the sample constitutes6 concrete cylinders From where was the sample collectedJob Site
First name of sampler or witnessed byYe Last name of sampler or witnessed byYang
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility name? Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design number176H57
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected161230
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collected161+00 Sign Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-12-05-62
DIME Test ID: 2023-12-05-62-1
Testing Lab: CT D06 - Millbrook Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2024-01-04

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Tomas Silva
Date of test: 01/02/2024
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 4.01 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 67070 lb
Maximum load on cylinder 2: 64580 lb
Maximum load on cylinder 3: 65960 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.63 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5310.4 psi
Compressive strength of cylinder 2: 5137.6 psi
Compressive strength of cylinder 3: 5247.4 psi
Compressive strength (to nearest 10 psi): 5230 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/4/2024