Summary for Test 2023-12-09-2-7
Test performed: CTM 226-July 2010Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | 11/17/2020 |
Closeout Date | 09/24/2024 |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 12/09/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/14/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1x4 PCC Aggregates |
The quantity of what the sample constitutes | 110 CY | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | victor | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | 2137924794 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Granite - Santa Barbara | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-19-0046 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | Mix G3-22PRS-299 | |
The plant number | Santa Barbara | A detailed description of where the material sample was collected | Conveyor Belt |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 1 inch | |
The concrete mix design number | G3-22PRS-299 | Lot number | |
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-12-09-2
DIME Test ID: 2023-12-09-2-7
Testing Lab: CT D07 - Plant Services
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2024-01-08
Test Results
Input Type: Measured
Tester's full name: A.Truong
Date of test: 12/14/2023
Wet weight of the sample: 292.0000000000 grams
Dry weight of the sample: 271.0000000000 grams
Weight of water in sample: 21.0000000000 grams
Percent moisture: 7.7 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/8/2024 ✔