Summary for Test 2023-12-18-47-2

Test performed: CTM 227-December 2014

Project Information

Project IdentifiersProject ID: 214649
DEA: 07316004
EFIS: 0715000194
DIST-CO-RTE-PM07-LA-14-60.70
Award Date02/07/2023
Closeout DateNot set
Work DescriptionREHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES.
Location DescriptionROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE.
QA Service Level1 (Verified on 01/29/2020)

Sample Information

Sample Taken Date12/18/2023 Sample Unique Key47
Date that the sample was received by the laboratory/organization performing the testing12/21/2023 Sample typeDepartment Acceptance
A brief description of the sample1x4 PCC Aggregates The quantity of what the sample constitutes470 cy
From where was the sample collectedManufacturer First name of sampler or witnessed byvictor
Last name of sampler or witnessed byPham Title of sampler
Telephone number of sampler2137924794 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameAtkinson - Lancaster
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0026
The fabricator's/manufacturer's product name for the sampleJPCP The fabricator/manufacturer designation for the samplemix SCI-12622-1
The plant numberAtkinson Portable Jobsite A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberSCI-12622-1 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-12-18-47
DIME Test ID: 2023-12-18-47-2
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: CTM 227-December 2014: Method of Test for Evaluating Cleanness of Coarse Aggregate (Cleanness)
Test Release Date: 2024-01-13

Test Results


Describe the gradation of the aggregate or the test method:: All aggregate is the same size
Input Type: Measured
Tester's full name: Victor Pham
Date of test: 12/21/2023
Top sediment column reading (single primary size): 0.6 in
Cleanness value (single primary size): 84
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/13/2024 ✔