Summary for Test 2017-04-21-8-2

Test performed: ASTM A615-15

Project Information

Project IdentifiersProject ID: 211588
DEA: 030F3104
EFIS: 0300000078
DIST-CO-RTE-PM03-ED-49-23.6/24.5
Award Date12/12/2016
Closeout Date01/08/2019
Work DescriptionREPLACE BRIDGE.
Location DescriptionEL DORADO COUNTY NEAR COLOMA FROM 0.1 MILE EAST OF MARSHALL ROAD TO 0.3 MILE EAST OF LOTUS ROAD
QA Service Level1 (Verified on 10/19/2016)

Sample Information

Sample Taken Date04/21/2017 Sample Unique Key8
Date that the sample was received by the laboratory/organization performing the testing04/26/2017 Sample typeQuality Assurance
A brief description of the sampleWilliams Thread Bars The quantity of what the sample constitutes2
From where was the sample collectedManufacturer First name of sampler or witnessed byKen
Last name of sampler or witnessed byVarela Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameWilliams Form
Transportation Laboratory (TL) NumberC939317 Inspector Lot Number from the Transportation Laboratory (TL) FormL0803817
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Threaded Bar Production or Authorization TestingProduction Testing
Threaded Bar SpecificationASTM A615 Threaded Bar Grade75
Threaded Bar TypeDeformed Rebar Size#9
Nut Specification for Threaded BarGrade 75 ATB System ManufacturerWilliams Form
Epoxy Coating ColorNA Threaded Bar ApplicationThreaded Bar
Coating StandardsUncoated Bar Heat Number(s)PL16207196
Nut Heat Number(s)NF15203512 Bar Lot NumberNA
Nut Lot Number9H5D Coupler Heat Number(s)NA
Coupler GradeNA

Test Details

DIME Sample ID: 2017-04-21-8
DIME Test ID: 2017-04-21-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A615-15: Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement (Tensile)
Test Release Date: 2017-05-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/27/2017
UTM: 400KIP
Temperature: 72 F
NumSampleSizeMfg LotArea (sqin)Tensile Strength (psi)Stress at Offset (psi)Total Elongation (%)CommentsTested By
12#9 Bar Heat #PL16207196, Nut Heat #9H5DL08038171109467802430A615 Bar & NutFred

General comments (publicly viewable) (Max 1000 characters): A615 Bar & Nut
Test Graph
Source: Partner Data Point File

Test was verified on 4/27/2017 ✔