Summary for Test 2023-12-28-16-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 994191 DEA: 081G8304 EFIS: 0816000079 |
---|---|
DIST-CO-RTE-PM | 08-SBD-40-R100.8/R101.8 |
Award Date | 12/01/2022 |
Closeout Date | Not set |
Work Description | HMA, STRUCTURAL CONC, BAR REINFORCING STEEL, CRSP & IMPORTED BORROW. |
Location Description | SAN BERNARDINO COUNTY AT ESSEX FROM 1.1 MILES EAST OF ESSEX ROAD OVERCROSSING TO 0.5 MILE EAST OF HALFWAY HILLS WASH BRIDGE |
QA Service Level | 1 (Verified on 03/30/2023) |
Sample Information
Sample Taken Date | 12/28/2023 | Sample Unique Key | 16 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/28/2023 |
Sample type | Quality Assurance | A brief description of the sample | CTM231 TEST 01 |
The quantity of what the sample constitutes | 297Square Feet | From where was the sample collected | Job Site |
First name of sampler or witnessed by | NATHAN | Last name of sampler or witnessed by | OGBASELIASIE |
Title of sampler | TE | Telephone number of sampler | |
Laboratory sample identification | 1228023 TEST 02 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | CTM 231 TEST LOCATION | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | AT THE JOBSITE | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-12-28-16
DIME Test ID: 2023-12-28-16-1
Testing Lab: CT D08 - Barstow Field Laboratory 1
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-12-29
Test Results
Method Type:: Standard Count
Number of Tests:: 3
Common Test Maximum Used:: No
Input Type: Measured
Tester's full name: NATHAN OGBASELIASIE
Date of test: 12/28/2023
Gage No.: 30690
Test No.: 2
Nuclear By: nathan ogbaseliasie
Non-Bias Plan No.: 2
Depth: 8
Material No.: stucural backfill
Material Type: NATIVE
Impact By: nathan ogbaseliasie
Standard Count Density: 1657 g/cc
Count or Density 1: 918 g/cc
Count or Density 2: 896 g/cc
Count or Density 3: 875 g/cc
Standard Count Moisture: 629 g/cc
Moisture Count 1: 139 g/cc
Moisture Count 2: 114 g/cc
Moisture Count 3: 112 g/cc
Sum of Count or Density: 2689.00 g/cc
Average of Count or Density: 896.00 g/cc
Sum of Moisture Count: 365.00 g/cc
Average of Moisture Count: 122.00 g/cc
Count Ratio Density: 0.54
Count Ratio Moisture: 0.19
Calculated Percent Relative Compaction: 93.4 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/29/2023 ✔