Summary for Test 2017-04-19-2-6
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 211794 DEA: 044G5104 EFIS: 0412000483 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-31.4,32.6 |
| Award Date | 01/20/2017 |
| Closeout Date | 09/12/2019 |
| Work Description | BRIDGE CONSTRUCTION |
| Location Description | SOLANO COUNTY IN AND NEAR VACAVILLE AT MERIDIAN ROAD OVERCROSSING AND AT MIDWAY ROAD OVERCROSSING |
| QA Service Level | 1 (Verified on 01/03/2017) |
Sample Information
| Sample Taken Date | 04/19/2017 | Sample Unique Key | 2 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 04/24/2017 |
| Sample type | Recertification | A brief description of the sample | Flash Welded Hoops |
| The quantity of what the sample constitutes | 10 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kevin | Last name of sampler or witnessed by | Muser |
| Title of sampler | QA | Telephone number of sampler | 9165170532 |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | CMC Rebar Tracy CA | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-100-17 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 4061696 |
| Hoop Manufacturer Lot Number(s) | 0 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | 8 |
| Diameter of Hoop | 2'-0" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | CMC Arizona |
| Welding Company | CMC Rebar (Tracy) | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-04-19-2
DIME Test ID: 2017-04-19-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2017-05-23
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/26/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Cycle-6 | 100 | #8/25mm | S1910017, H & H Welder #H6020R | 0.79 | 72136 | 91311 | Bar Broke in Heat Affected Zone | Fred |
General comments (publicly viewable) (Max 1000 characters): Bar Broke in Heat Affected Zone; Brittle Brake
Test Graph
Source: Partner Data Point FileTest was verified on 5/16/2017 ✔