Summary for Test 2023-12-18-30-1
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 215677 DEA: 044G0804 EFIS: 0412000332 COOP: 042676 |
|---|---|
| DIST-CO-RTE-PM | 04-SOL-80-R10.4/30.2 |
| Award Date | 01/18/2022 |
| Closeout Date | Not set |
| Work Description | Highway widening, overhead signs, and electronic toll system. |
| Location Description | In Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing. |
| QA Service Level | 1 (Verified on 04/11/2022) |
Sample Information
| Sample Taken Date | 12/18/2023 | Sample Unique Key | 30 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/27/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Fastener Assembly |
| The quantity of what the sample constitutes | 464 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Oscar | Last name of sampler or witnessed by | Vizcaino |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Madison, IL | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | 1000221590 234145 132068 | Nut Mfg. Lot Number(s) | 39225-234145 |
| Washer Mfg. Lot Number(s) | 0723-809 | Bolt Specification | A325 |
| Bolt Length(s) | 5 | Nut Specification | A563 |
| Washer Specification | F436 | Finish | MG |
| Diameter/Size | 7/8 | Bolt Mfg. Lot Number | 38950-1000221590 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2023-12-18-30
DIME Test ID: 2023-12-18-30-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-01-04
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/29/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1A | 75712 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 1/4/2024 ✔