Summary for Test 2023-12-18-26-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 215677
DEA: 044G0804
EFIS: 0412000332
COOP: 042676
DIST-CO-RTE-PM04-SOL-80-R10.4/30.2
Award Date01/18/2022
Closeout DateNot set
Work DescriptionHighway widening, overhead signs, and electronic toll system.
Location DescriptionIn Solano County in Fairfield and Vacaville from 1.0 mile west of Red Top Road Undercrossing to 0.4 mile east of Leisure Town Road Overcrossing.
QA Service Level1 (Verified on 04/11/2022)

Sample Information

Sample Taken Date12/18/2023 Sample Unique Key26
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/27/2023
Sample typeQuality Assurance A brief description of the sampleFastener Assembly
The quantity of what the sample constitutes275 From where was the sample collectedManufacturer
First name of sampler or witnessed byOscar Last name of sampler or witnessed byVizcaino
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMadison, IL Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10851370 234284 42316930 Nut Mfg. Lot Number(s)39225-234284
Washer Mfg. Lot Number(s)0623-772 Bolt SpecificationA325
Bolt Length(s)2 Nut SpecificationA563
Washer SpecificationF436 FinishMG
Diameter/Size7/8 Bolt Mfg. Lot Number39192-10851370
Rocap Test Requirement(s) Lubricant Requirements(s)
Washer Inner Diameter(s)

Test Details

DIME Sample ID: 2023-12-18-26
DIME Test ID: 2023-12-18-26-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2024-01-04

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 12/29/2023
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A75638Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 1/4/2024