Summary for Test 2023-08-07-90-3
Test performed: AASHTO T209-12Project Information
| Project Identifiers | Project ID: 215157 DEA: 021H5704 EFIS: 0216000036 |
|---|---|
| DIST-CO-RTE-PM | 02-SHA-299-67.8/77.8 |
| Award Date | 02/09/2023 |
| Closeout Date | 06/11/2024 |
| Work Description | BURNEY CAPM - PAVEMENT REHABILITATION |
| Location Description | BUNCH GRASS LOOKOUT RD TO NAPA LN |
| QA Service Level | 1 (Verified on 09/03/2020) |
Sample Information
| Sample Taken Date | 08/07/2023 | Sample Unique Key | 90 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 08/07/2023 | Sample type | Production Start-Up |
| A brief description of the sample | 1 bag of Combined RAP (3/8-inch) | The quantity of what the sample constitutes | Production Start-Up Evaluation |
| From where was the sample collected | Manufacturer | First name of sampler or witnessed by | Cindy |
| Last name of sampler or witnessed by | Bryant | Title of sampler | |
| Telephone number of sampler | Laboratory sample identification | D79307B | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | J.F. Shea Construction — Fawndale Rock and Asphalt (Redding, CA) | |
| Transportation Laboratory (TL) Number | 857939 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Reclaimed Asphalt Pavement | RAP Source | Fawndale Rock and Asphalt, Redding, CA |
|---|---|---|---|
| Aggregate Size | 3/8-inch | Aggregate Source | |
| RAP Stockpile | Stockpile Size (tons) | ||
| Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2023-08-07-90
DIME Test ID: 2023-08-07-90-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-12-28
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 08/11/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.1 grams
Mass of oven-dry sample in air for Sample 1: 2549.5 grams
Mass of container filled with the sample and water for Sample 1: 8903.2 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.598
Theoretical maximum density at 25°C (77°F): 2590.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.598,
Gser≈2.790
Test was verified on 12/28/2023 ✔