Summary for Test 2023-11-10-65-2
Test performed: ASTM D36-14ε1Project Information
| Project Identifiers | Project ID: 994751 DEA: 010C5004 EFIS: 0112000292 |
|---|---|
| DIST-CO-RTE-PM | 01-HUM-36-11.3/34.6 |
| Award Date | 03/02/2023 |
| Closeout Date | Not set |
| Work Description | Project Name: Bridge Rail Replacement - 3 Bridges |
| Location Description | Hely Creek, Little Larabee Creek and Butte Creek Bridge. |
| QA Service Level | 1 (Verified on 04/27/2023) |
Sample Information
| Sample Taken Date | 11/10/2023 | Sample Unique Key | 65 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 12/22/2023 | Sample type | Verification |
| A brief description of the sample | 1/2" RHMA-G - Paving | The quantity of what the sample constitutes | 1 can RHMA |
| From where was the sample collected | Supplier | First name of sampler or witnessed by | John |
| Last name of sampler or witnessed by | Atturo | Title of sampler | Plant QC |
| Telephone number of sampler | Laboratory sample identification | 23-339 | |
| Linked DIME Sample ID | 2023-11-10-63 | The fabricator/manufacturer/facility name | Mercer Fraser Boyd Road |
| Transportation Laboratory (TL) Number | 930385 | Inspector Lot Number from the Transportation Laboratory (TL) Form | |
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
|---|---|---|---|
| Performance Grade | PG 64-16 | Lot number | |
| Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2023-11-10-65
DIME Test ID: 2023-11-10-65-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2023-12-28
Test Results
ASTM Thermometer used?: C
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 12/27/2023
Softening Point Sample 1: 65 C
Softening Point Sample 2: 64 C
Bath Liquid: freshly boiled distilled water
Minutes Reaction: no data
General comments (publicly viewable) (Max 1000 characters): softening point
Test was verified on 12/28/2023 ✔