Summary for Test 2017-04-21-6-1
Test performed: ASTM C39-17aProject Information
| Project Identifiers | Project ID: 208714 DEA: 08043514 EFIS: 0800000010 |
|---|---|
| DIST-CO-RTE-PM | 08-SBD-58-R22.2/R31.1 |
| Award Date | 12/30/2014 |
| Closeout Date | 08/29/2018 |
| Work Description | REALIGN AND WIDEN 2 TO 4 LANES EXPRESSWAY |
| Location Description | HINKLEY ROAD FROM 2.4 MILES WEST OF HIDDEN RIVER ROAD TO? 0.7 MILE EAST OF LENWOOD ROAD. |
| QA Service Level | 1 (Verified on 03/22/2013) |
Sample Information
| Sample Taken Date | 04/21/2017 | Sample Unique Key | 6 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 04/25/2017 | Sample type | Quality Control |
| A brief description of the sample | 6X12 | The quantity of what the sample constitutes | 6 |
| From where was the sample collected | Job Site | First name of sampler or witnessed by | ROBERT |
| Last name of sampler or witnessed by | BIRBACH | Title of sampler | ASR |
| Telephone number of sampler | Unknown | Laboratory sample identification | 915-421 |
| Linked DIME Sample ID | Unknown | The fabricator/manufacturer/facility name | ROBERTSONS |
| Transportation Laboratory (TL) Number | 20170421 | Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown |
| Structure unique identifier | RW1633 POUR 1 | Structure name | Unknown |
| Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | NP |
|---|---|---|---|
| The truck number from where the sample was collected | 8012225 | The batch plant ticket number from where the sample was collected | 2298552 |
| Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
| A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Unknown |
| From Lot No. | Unknown | Bag Lot No. | Unknown |
Test Details
DIME Sample ID: 2017-04-21-6
DIME Test ID: 2017-04-21-6-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2017-04-26
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 04/25/2017
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.97 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 73960 lb
Maximum load on cylinder 2: 72560 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: no data
Age of specimen: 4 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 27.99 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 2642.4 psi
Compressive strength of cylinder 2: 2583.1 psi
Compressive strength (to nearest 10 psi): 2610 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/26/2017 ✔