Summary for Test 2023-11-14-66-1
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 214486 DEA: 080K1224 EFIS: 0815000244 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15-R28.6/37.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | REHBILIATATE EXISTING MAINLINE AND RAMP PAVEMENT |
Location Description | SAN BERNARDINO COUNTY IN HESPERIA AND VICTORVILLE FROM OAK HILL ROAD OVERCROSSING TO 0.1 MILE SOUTH OF BEAR VALLEY ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 06/23/2021) |
Sample Information
Sample Taken Date | 11/14/2023 | Sample Unique Key | 66 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/14/2023 |
Sample type | Quality Assurance | A brief description of the sample | 6X12 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jareerattana | Last name of sampler or witnessed by | Sirisujarittham |
Title of sampler | QA Consultant | Telephone number of sampler | |
Laboratory sample identification | 1042-1114 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | SULLY Miller | Transportation Laboratory (TL) Number | 1042-1114 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G3-22-PCC-273 |
---|---|---|---|
The truck number from where the sample was collected | Not Provided on TL | The batch plant ticket number from where the sample was collected | 21 |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | SB I15 STAGE 2A JPCP LN 1STA 131.65 - 131.45 | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-11-14-66
DIME Test ID: 2023-11-14-66-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-12-26
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With density determined by dimension measurements
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 12/26/2023
In air mass of cylinder 1: 28.8 lb
In air mass of cylinder 2: 28.86 lb
In air mass of cylinder 3: 29.12 lb
Length of cylinder 1: 12 in
Length of cylinder 2: 12 in
Length of cylinder 3: 12 in
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 5.98 in
Average diameter of cylinder 3: 5.99 in
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Density of cylinder 1: 147 lb/ft^3
Density of cylinder 2: 148 lb/ft^3
Density of cylinder 3: 149 lb/ft^3
Average cylinder density (to nearest 1 pcf): 148 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
Comp. Strength Report1042-1114 | 204.71 KB | 12/26/2023 | 2023-11-14-66-1 | Info |
Test was verified on 12/26/2023 ✔