Summary for Test 2023-10-30-88-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 214649
DEA: 07316004
EFIS: 0715000194
DIST-CO-RTE-PM07-LA-14-60.70
Award Date02/07/2023
Closeout DateNot set
Work DescriptionREHABILITATION FOR THE ON/OFF RAMPS AND ADJACENT SHOULDERS. UPGRADING METAL BEAM GUARDRAILS, AC DIKES, SIGN PANELS, CURB RAMPS, TRAFFIC LOOPS DETECTORS, AND SOME OTHER HIGHWAY APPURTENANCES.
Location DescriptionROUTE 14 FROM PALMDALE BLVD TO KERN COUNTRY LINE.
QA Service Level1 (Verified on 01/29/2020)

Sample Information

Sample Taken Date10/30/2023 Sample Unique Key88
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/31/2023
Sample typeDepartment Acceptance A brief description of the sampleCoarse and fine aggregate
The quantity of what the sample constitutesTwo Bags From where was the sample collectedManufacturer
First name of sampler or witnessed byBaher Last name of sampler or witnessed byFakhoury
Title of sampler Telephone number of sampler2137937180
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameATKINSON CONSTRUCTION Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0042
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Sizefine
The concrete mix design numberSCI-12622-1A Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-10-30-88
DIME Test ID: 2023-10-30-88-1
Testing Lab: CT D07 - Plant Services
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-12-26

Test Results


What size aggregate is being tested?: Fine Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Measured
Tester's full name: Baher Fakhoury
Date of test: 10/31/2023
Sieve SizeCumulative Mass RetainedCumulative Percent Passing
518 grams
0.0 grams100 %
0.0 grams100 %
73.0 grams86 %
184.0 grams64 %
289.0 grams44 %
394.0 grams24 %
458.0 grams12 %
489.0 grams6 %
491.0 grams
General comments (publicly viewable) (Max 1000 characters): The fine aggregate gradation is out of operating range but within contract compliance on sieve # 50

Test was verified on 12/26/2023