Summary for Test 2023-12-14-33-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 993446 DEA: 120J34U4 EFIS: 1218000034 |
|---|---|
| DIST-CO-RTE-PM | 12-ORA-55,55-29.6,R6.4/10.3 |
| Award Date | 05/27/2022 |
| Closeout Date | Not set |
| Work Description | CONSTR BRIDGES, RW, SW, JPCP, HMA PVMT, DRAINAGE AND ELECT SYSTEMS. |
| Location Description | ORANGE COUNTY IN IRVINE, SANTA ANA, AND TUSTIN ON ROUTE 5 AT NEWPORT AVENUE UNDERCROSSING AND ON ROUTE 55 FROM 0.4 MILE NORTH OF ROUTE 55/405 SEPARATION TO 0.1 MILE SOUTH OF ROUTE 5/55 SEPARATION |
| QA Service Level | 1 (Verified on 06/24/2022) |
Sample Information
| Sample Taken Date | 12/14/2023 | Sample Unique Key | 33 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/18/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Hoops |
| The quantity of what the sample constitutes | 1234 | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Joaquin | Last name of sampler or witnessed by | Moreno |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Cascade | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Ultimate | Rebar Heat Number(s) | 273422 |
| Hoop Manufacturer Lot Number(s) | 16 and 20 | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Size | #6 |
| Diameter of Hoop | 1'-6" | Epoxy Coated | No |
| Epoxy Coating Color | NA | Rebar Manufacturer | Cascade |
| Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
| Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2023-12-14-33
DIME Test ID: 2023-12-14-33-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2023-12-28
Test Results
Number of Samples: 6
Input Type: Measured
Tester's full name: Andrew Auvinen
Date of test: 12/19/2023
UTM: 400KIP
Temperature: 72 f
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 16 | 6 | 0.44 | 41493.87 | 94304 | Ok Necking | A Auvinen |
| 2 | 2 | 16 | 6 | 0.44 | 41478.96 | 94270 | Ok Necking | A Auvinen |
| 3 | 3 | 16 | 6 | 0.44 | 41644.95 | 94648 | Ok Necking | A Auvinen |
| 4 | 1 | 20 | 6 | 0.44 | 42041.57 | 95549 | Ok Necking | A Auvinen |
| 5 | 2 | 20 | 6 | 0.44 | 41978.46 | 95406 | Ok Necking | A Auvinen |
| 6 | 3 | 20 | 6 | 0.44 | 41967.91 | 95382 | Ok Necking | A Auvinen |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/28/2023 ✔