Summary for Test 2023-12-15-33-1

Test performed: AASHTO T11-5

Project Information

Project IdentifiersProject ID: 214708
DEA: 07323904
EFIS: 0716000072
DIST-CO-RTE-PM07---
Award Date03/27/2023
Closeout DateNot set
Work DescriptionCOLD PLANE AC, PLACE RUBBERIZED HOT MIX AS
Location DescriptionVENTURA COUNTY NEAR VENTURA FROM ROUTE 1/101 SEPARATION TO MOBIL PIER ROAD.
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date12/15/2023 Sample Unique Key33
Date that the sample was received by the laboratory/organization performing the testing12/15/2023 Sample typeDepartment Acceptance
A brief description of the sample1/2" RHMA-G The quantity of what the sample constitutesSample 2 of the day @ 750-1500 Tons
From where was the sample collectedManufacturer First name of sampler or witnessed byKevin
Last name of sampler or witnessed byHopkins Title of samplerPlant Inspector
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan Materials HMA - Saticoy
Transportation Laboratory (TL) NumberC121523F Inspector Lot Number from the Transportation Laboratory (TL) FormKH206F
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0020, 91-19-0035
The fabricator's/manufacturer's product name for the sample326122 SAT VLO The fabricator/manufacturer designation for the sample
The plant numberVulcan Saticoy HMA A detailed description of where the material sample was collectedConveyor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-12-15-33
DIME Test ID: 2023-12-15-33-1
Testing Lab: CT D07 - Plant Services, Unit 1841
Test Method: AASHTO T11-5: Standard Method of Test for Materials Finer Than 75-μm (No. 200) Sieve in Mineral Aggregates by Washing
Test Release Date: 2023-12-20

Test Results


Input Type: Measured
Tester's full name: Kevin Hopkins
Date of test: 12/19/2023
Which test procedure is being used: Method A
Mass of test sample (before test): 391 grams
Mass of test sample (after test): 355 grams
Percent of sample passing the #200 sieve (by mass): 9.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/20/2023 ✔