Summary for Test 2023-05-10-98-1

Test performed: CTM 216-June 2011

Project Information

Project IdentifiersProject ID: 993424
DEA: 04281204
EFIS: 0400000769
DIST-CO-RTE-PM04-NAP-29,221-5.5/6.7,0.0/0.2
Award Date03/21/2022
Closeout DateNot set
Work DescriptionHMA, RDWY EXCAVATION, STRUCTURAL CONC AND MODIFYING LIGHTING SYSTEMS.
Location DescriptionNAPA COUNTY NEAR NAPA ON ROUTE 29 FROM 0.7 MILE SOUTH TO 0.5 MILE NORTH OF ROUTE 221 AND ON ROUTE 221 FROM 0.2 MILE NORTH OF ROUTE 29 TO ROUTE 29
QA Service Level1 (Verified on 12/08/2021)

Sample Information

Sample Taken Date05/10/2023 Sample Unique Key98
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/10/2023
Sample typeQuality Assurance A brief description of the sampleSubgrade
The quantity of what the sample constitutes2500 Grams From where was the sample collectedJob Site
First name of sampler or witnessed byIGNACIO Last name of sampler or witnessed byARECHIGA
Title of sampler Telephone number of sampler5102077252
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNative Material Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeSoil The fabricator's/manufacturer's product name for the sample
The fabricator/manufacturer designation for the sample A detailed description of where the material sample was collectedG 1 LINE
Where the material sample would have been placed if not sampled

Test Details

DIME Sample ID: 2023-05-10-98
DIME Test ID: 2023-05-10-98-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 216-June 2011: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates
Test Release Date: 2023-12-19

Test Results


Is oversize material: Yes
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 05/10/2023
In-place wet density: 2.13
% Moisture: 12.1 %
Optimum Moisture: 10.1 %
Corrected density: 2.24
Relative compaction: 96
General comments (publicly viewable) (Max 1000 characters): Results reported to the inspector on 5-10-2023

Test was verified on 12/19/2023