Summary for Test 2023-04-13-84-2
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 993424 DEA: 04281204 EFIS: 0400000769 |
---|---|
DIST-CO-RTE-PM | 04-NAP-29,221-5.5/6.7,0.0/0.2 |
Award Date | 03/21/2022 |
Closeout Date | Not set |
Work Description | HMA, RDWY EXCAVATION, STRUCTURAL CONC AND MODIFYING LIGHTING SYSTEMS. |
Location Description | NAPA COUNTY NEAR NAPA ON ROUTE 29 FROM 0.7 MILE SOUTH TO 0.5 MILE NORTH OF ROUTE 221 AND ON ROUTE 221 FROM 0.2 MILE NORTH OF ROUTE 29 TO ROUTE 29 |
QA Service Level | 1 (Verified on 12/08/2021) |
Sample Information
Sample Taken Date | 04/13/2023 | Sample Unique Key | 84 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/13/2023 |
Sample type | Quality Assurance | A brief description of the sample | Native Subgrade |
The quantity of what the sample constitutes | 2500 Grams | From where was the sample collected | Job Site |
First name of sampler or witnessed by | IGNACIO | Last name of sampler or witnessed by | ARECHIGA |
Title of sampler | Telephone number of sampler | 5102077252 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Native Material | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | G1 Line | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-04-13-84
DIME Test ID: 2023-04-13-84-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-12-18
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: No
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 04/13/2023
Sum of Count or Density: 129055 g/cc
Average of Count or Density: 25811 g/cc
Sum of Moisture Count: 15612 g/cc
Average of Moisture Count: 3122 g/cc
Count Ratio Density: 29962
Count Ratio Moisture: 9046
Calculated Percent Relative Compaction: 97.7 %
Reported Percent Relative Compaction: 98 %
General comments (publicly viewable) (Max 1000 characters): Results reported to the inspector on 4-13-2023
Test was verified on 12/18/2023 ✔