Summary for Test 2017-04-18-3-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211235
DEA: 054482U4
EFIS: 0500000543
DIST-CO-RTE-PM05-SB-101-2.2/3.3
Award Date06/20/2016
Closeout Date08/23/2021
Work DescriptionBUILD AND RECONSTRUCT BRIDGES, CONSTRUCT RAMPS AND FRONTAGE ROAD.
Location DescriptionSANTA BARBARA COUNTY IN CARPINTERIA FROM 0.2 MILE SOUTH OF CARPINTERIA CREEK BRIDGE TO FRANKLIN CREEK BRIDGE
QA Service Level1 (Verified on 07/27/2016)

Sample Information

Sample Taken Date04/18/2017 Sample Unique Key3
Date that the sample was received by the laboratory/organization performing the testing04/19/2017 Sample typeQuality Assurance
A brief description of the sampleFlash Welded Rebar Hoops The quantity of what the sample constitutes8
From where was the sample collectedFabricator First name of sampler or witnessed byEd
Last name of sampler or witnessed byFleming Title of samplerUnknown
Telephone number of samplerUnknown Laboratory sample identificationUnknown
Linked DIME Sample IDUnknown The fabricator/manufacturer/facility nameHarris Salinas
Transportation Laboratory (TL) NumberC739979 Inspector Lot Number from the Transportation Laboratory (TL) FormB1016217
Structure unique identifierNot set Structure nameNot set
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)586349
Hoop Manufacturer Lot Number(s)H03, H04 Material Standard CodeASTM A706
Material Grade60 Rebar Size4
Diameter of Hoop1'-6" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerHarris Salinas
Welding CompanyHarris Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-04-18-3
DIME Test ID: 2017-04-18-3-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 04/20/2017
UTM: 75KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13H03#4/13mm0.21842392120necking okayBrian

General comments (publicly viewable) (Max 1000 characters): necking okay
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 4/20/2017 ✔