Summary for Test 2023-11-28-35-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 214337
DEA: 080E33U4
EFIS: 0817000075
DIST-CO-RTE-PM08-SBD-115-R7.3/R10.0
Award Date04/26/2021
Closeout Date06/09/2025
Work DescriptionADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location DescriptionSAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date11/28/2023 Sample Unique Key35
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/04/2023
Sample typeDepartment Acceptance A brief description of the sample3/4" HMA-A R15 NO LAS
The quantity of what the sample constitutes2 BOXES OF HHA From where was the sample collectedManufacturer
First name of sampler or witnessed byPLANT QC Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0592A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAAA- CORONA/SJR Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number105927
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-11-28-35
DIME Test ID: 2023-11-28-35-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 12/05/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2170.4 g
Mass Loss: 111.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.09 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.06 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.98 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/12/2023