Summary for Test 2023-11-29-28-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994226 DEA: 042K7004 EFIS: 0417000010 COOP: 042895 |
---|---|
DIST-CO-RTE-PM | 04-ALA-880-R0.0/11.8 |
Award Date | 07/13/2023 |
Closeout Date | Not set |
Work Description | Cold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE) |
Location Description | ALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 11/29/2023 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/30/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA + 25% RAP |
The quantity of what the sample constitutes | 150 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Holie | Last name of sampler or witnessed by | Sada |
Title of sampler | Plant QC Tech | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan-Pleasanton | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | D04 JMF 22 008 |
Test Details
DIME Sample ID: 2023-11-29-28
DIME Test ID: 2023-11-29-28-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-12
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Luis Magana
Date of test: 11/30/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2095.6 g
Mass Loss: 117.5 g
Correction Factor (Percent by mass of HMA Specimen): 1.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.47 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/12/2023 ✔