Summary for Test 2023-11-29-28-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994226
DEA: 042K7004
EFIS: 0417000010
COOP: 042895
DIST-CO-RTE-PM04-ALA-880-R0.0/11.8
Award Date07/13/2023
Closeout DateNot set
Work DescriptionCold plane pavement and overlay with RHMA-G/RHMA-O (CAPITAL PREVENTIVE MAINTENANCE)
Location DescriptionALAMEDA COUNTY IN FREMONT AND NEWARK FROM SANTA CLARA COUNTY LINE TO 0.4 MILE NORTH OF FREMONT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 09/13/2022)

Sample Information

Sample Taken Date11/29/2023 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/30/2023
Sample typeQuality Assurance A brief description of the sample3/4 HMA + 25% RAP
The quantity of what the sample constitutes150 Tons From where was the sample collectedSupplier
First name of sampler or witnessed byHolie Last name of sampler or witnessed bySada
Title of samplerPlant QC Tech Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan-Pleasanton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberD04 JMF 22 008

Test Details

DIME Sample ID: 2023-11-29-28
DIME Test ID: 2023-11-29-28-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Luis Magana
Date of test: 11/30/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2095.6 g
Mass Loss: 117.5 g
Correction Factor (Percent by mass of HMA Specimen): 1.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.13 %
Test Temperature: 482 C
Corrected Asphalt Binder Content: 4.47 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 12/12/2023