Summary for Test 2023-11-27-30-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212571
DEA: 051F79A4
EFIS: 0514000061
DIST-CO-RTE-PM05-SB-101-55.9/R56.2
Award Date09/13/2022
Closeout Date07/02/2026
Work DescriptionNojoqui Creek Bridge (51-0018 L/R) widening and rail replacement.
Location DescriptionIN SANTA BARBARA COUNTY NEAR BUELLTON AT NOJOQUI CREEK BRIDGE (BR #51-0018 L/R)
QA Service Level1 (Verified on 02/20/2020)

Sample Information

Sample Taken Date11/27/2023 Sample Unique Key30
Date that the sample was received by the laboratory/organization performing the testing12/11/2023 Sample typeQuality Assurance
A brief description of the sample#8 Bar Lock Coupler The quantity of what the sample constitutes4
From where was the sample collectedJob Site First name of sampler or witnessed byGhilton
Last name of sampler or witnessed byGhilton Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameNucor Dayton Superior
Transportation Laboratory (TL) Number231127 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#8 Coupler ModelBar Lock S/CA
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)4000005510 Rebar Heat Number(s)3500032057
Rebar Size 2 Coupler Unique IDSL-17-01

Test Details

DIME Sample ID: 2023-11-27-30
DIME Test ID: 2023-11-27-30-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-12-12

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 12/11/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 8/25mm100.795985375763Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 12/12/2023 ✔