Summary for Test 2023-10-26-92-1

Test performed: AASHTO T176-08

Project Information

Project IdentifiersProject ID: 994745
DEA: 040Y2304
EFIS: 0422000258
DIST-CO-RTE-PM04-NAP-29-0.0/5.1
Award Date03/08/2023
Closeout Date01/10/2024
Work DescriptionCold plane AC pavement and place HMA (A).
Location DescriptionCONSTRUCTION ON STATE HIGHWAY IN NAPA COUNTY IN AND NEAR AMERICAN CANYON FROM SOLANO COUNTY LINE TO 0.4 MILE NORTH OF AIRPORT BOULEVARD.
QA Service Level1 (Verified on 05/10/2023)

Sample Information

Sample Taken Date10/26/2023 Sample Unique Key92
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing12/06/2023
Sample typeQuality Assurance A brief description of the sample3/4-INCH HMA-SP Type A
The quantity of what the sample constitutesSample 1 of the day From where was the sample collectedSource
First name of sampler or witnessed byIGNACIO Last name of sampler or witnessed byARECHIGA
Title of sampler Telephone number of sampler5102077252
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Vallejo Drier Drum Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-48-0002
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedSample Pick-Up From Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number220991W

Test Details

DIME Sample ID: 2023-10-26-92
DIME Test ID: 2023-10-26-92-1
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2023-12-11

Test Results


How many times will the test be run?: Once
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 12/06/2023
Sand Equivalent: 70
General comments (publicly viewable) (Max 1000 characters): Sample 1 of the day Vulcan Vallejo Drier Drum Plant

Test was verified on 12/11/2023