Summary for Test 2023-10-27-84-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993804
DEA: 043J0624
EFIS: 0419000534
DIST-CO-RTE-PM04-SM-101-16.5/23.0
Award Date08/24/2022
Closeout Date04/10/2024
Work DescriptionCOLD PLANE AND PLACE HMA, REPLACE GUARDRAIL AND CURB RAMPS.
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATION FROM BROADWAY OVERCROSSING TO 0.2 MILE NORTH OF OYSTER POINT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 05/19/2022)

Sample Information

Sample Taken Date10/27/2023 Sample Unique Key84
Date that the sample was received by the laboratory/organization performing the testing10/27/2023 Sample typeProduction Start-Up
A brief description of the sample1/2 RHMA-O HMA The quantity of what the sample constitutes750 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byHolie
Last name of sampler or witnessed bySada Title of samplerPlant QC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Pleasanton
Transportation Laboratory (TL) NumberC666437 Inspector Lot Number from the Transportation Laboratory (TL) FormLot 1 Sublot 1
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeOGFC
HMA Grading1/2 inch Lot number1
Sublot number1 HMA Mix NumberD04 OGFC 22 001
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-10-27-84
DIME Test ID: 2023-10-27-84-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-12-12

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Leonardo Mendoza
Date of test: 11/06/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1536.9 g
Mass Loss: 138.2 g
Correction Factor (Percent by mass of HMA Specimen): 0.97 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.20 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.80 %
General comments (publicly viewable) (Max 1000 characters): Lot 1 Sublot 1 Asphalt Content #1

Test was verified on 12/12/2023 ✔