Summary for Test 2023-09-20-123-2

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 993804
DEA: 043J0624
EFIS: 0419000534
DIST-CO-RTE-PM04-SM-101-16.5/23.0
Award Date08/24/2022
Closeout Date04/10/2024
Work DescriptionCOLD PLANE AND PLACE HMA, REPLACE GUARDRAIL AND CURB RAMPS.
Location DescriptionSAN MATEO COUNTY AT VARIOUS LOCATION FROM BROADWAY OVERCROSSING TO 0.2 MILE NORTH OF OYSTER POINT BOULEVARD OVERCROSSING
QA Service Level1 (Verified on 05/19/2022)

Sample Information

Sample Taken Date09/20/2023 Sample Unique Key123
Date that the sample was received by the laboratory/organization performing the testing09/21/2023 Sample typeQuality Assurance
A brief description of the sample3/4 RHMA-G Cold Feed Aggregate The quantity of what the sample constitutes750 Tons
From where was the sample collectedSupplier First name of sampler or witnessed byHolie
Last name of sampler or witnessed bySada Title of samplerPlant QC
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameVulcan-Pleasanton
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormLot 1 Sublot 20
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-01-0010
The fabricator's/manufacturer's product name for the sample226108 The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedPlant Sampler
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number1
Sublot number20 Aggregate Mix Number

Test Details

DIME Sample ID: 2023-09-20-123
DIME Test ID: 2023-09-20-123-2
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-12-22

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Measured
Tester's full name: Luis Magana
Date of test: 09/21/2023
Cumulative Mass RetainedCumulative Percent Passing
5218.0 grams
0.0 grams100 %
0.0 grams100 %
0.0 grams100 %
65.0 grams99 %
800.0 grams85 %
1795.0 grams66 %
3120.0 grams40 %
478 grams
269.0 grams17 %
349.0 grams11 %
386.0 grams8 %
414.0 grams5 %
438.0 grams3 %
450.3 grams2.3 %
450.7 grams
General comments (publicly viewable) (Max 1000 characters): Lot 1 Sublot 20

Test was verified on 12/22/2023 ✔