Summary for Test 2017-04-14-1-29

Test performed: ASTM B499-14

Project Information

Project IdentifiersProject ID: 210041
DEA: 043G4864
EFIS: 0412000086
DIST-CO-RTE-PM04-SM-92-14.4/18.8
Award Date12/18/2015
Closeout Date08/22/2018
Work DescriptionCLEAN AND PAINT STRUCTURAL STEEL ON BRIDGE
Location DescriptionIN SAN MATEO AND ALAMEDA COUNTIES ON ROUTE 92 AT SAN MATEO HAYWARD
QA Service Level1 (Verified on 11/05/2014)

Sample Information

Sample Taken Date04/14/2017 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing04/14/2017
Sample typeQuality Assurance A brief description of the sample1-8 x 3 Heavy Hex bolt
The quantity of what the sample constitutes1050 From where was the sample collectedDistributor
First name of sampler or witnessed byStacey Last name of sampler or witnessed byDavis
Title of samplerQAI Telephone number of sampler562 480-6984
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePacific Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormB362-031-17 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)L14121101, L1412102, L1412103
Heat Number(s)DL16102022, DL16100848, 100885294 Nut Mfg. Lot Number(s)24618-166642
Washer Mfg. Lot Number(s)D2553 Bolt SpecificationASTM A325
Bolt Length(s)3", 3 1/2", 5 1/2" Nut SpecificationASTM A563
Washer SpecificationASTM F436 FinishMechanical Galvanize
Diameter/Size1" (all) Bolt Mfg. Lot Number386534A, 379757A, 388587A
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2017-04-14-1
DIME Test ID: 2017-04-14-1-29
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-04-25

Test Results


Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 04/17/2017
Sample No.: 3D
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 88587A
Finish Coating: ASTM B695 - Mech Galv
Product Markings: A325 N
Size: 1 in
Bolt Length: 5.5 in
Measurement Average: 2.87 mils
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 4/18/2017