Summary for Test 2017-04-12-5-1
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 212164 DEA: 051J1304 EFIS: 0517000064 |
---|---|
DIST-CO-RTE-PM | 05-MON,MON-1-45.52, 45.4/45.8 |
Award Date | 02/16/2017 |
Closeout Date | 10/25/2019 |
Work Description | Pfeiffer Canyon Emergency Bridge Replacement Project |
Location Description | Highway 1 at Pfeiffer State Park |
QA Service Level | 1 (Verified on 02/27/2017) |
Sample Information
Sample Taken Date | 04/12/2017 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/12/2017 |
Sample type | Quality Assurance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Ed | Last name of sampler or witnessed by | Fleming |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Harris Salinas | Transportation Laboratory (TL) Number | C741367 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B1015217 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | SE17101189 |
Hoop Manufacturer Lot Number(s) | H02 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 8 |
Diameter of Hoop | 4'-2" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Harris Salinas |
Welding Company | Harris Rebar | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-04-12-5
DIME Test ID: 2017-04-12-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-24
Test Results
Number of Samples: 3
Input Type: Measured
Tester's full name: Fred Saylor
Date of test: 04/14/2017
UTM: 2000KIP
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 1 | H02 | #8 | 0.79 | 73540 | 93089 | OK Necking | Brian |
2 | 2 | H02 | #8 | 0.79 | 76009 | 96215 | OK Necking | Brian |
3 | 3 | H02 | #8 | 0.79 | 75709 | 95835 | OK Necking | Brian |
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/17/2017 ✔