Summary for Test 2023-09-11-95-5

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 993856
DEA: 042J7304
EFIS: 0415000004
DIST-CO-RTE-PM04-SM-101-6.7/7.6
Award Date03/20/2023
Closeout DateNot set
Work DescriptionSM 101 Cordilleras Crk Br Replacement
Location DescriptionNot set
QA Service Level1 (Verified on 06/27/2022)

Sample Information

Sample Taken Date09/11/2023 Sample Unique Key95
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2023
Sample typeQuality Control A brief description of the sampleDOT Class 1 5000psi@28 days 4" slump 0.4 w/c ratio 1" agg
The quantity of what the sample constitutes 16 CY From where was the sample collectedJob Site
First name of sampler or witnessed bySteve Olsen Last name of sampler or witnessed byVikram Kyatham
Title of samplerPrincipal Engineer Telephone number of sampler412 999 3719
Laboratory sample identification432350 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCentral Concrete Supply Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name35-0019

Material Information

Material TypeConcrete The concrete mix design numberD101C5E1
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected432350
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedAbutment 1 Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-09-11-95
DIME Test ID: 2023-09-11-95-5
Testing Lab: Myers and Sons Construction
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-11-29

Test Results


Unit system used?: US Units
Number of specimens: 1
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Steve Olsen
Date of test: 09/15/2023
Capped in accordance with?: ASTM C39 - Ground End
Average diameter of cylinder 1: 8.00 in
Maximum load on cylinder 1: 85030 lb
Type of fracture pattern of cylinder 1: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Compressive strength of cylinder (to nearest 10 psi): 6890 psi
General comments (publicly viewable) (Max 1000 characters):

Test File Attachments

File NameExtensionFile SizeDate UploadedTest IDActions
Concrete Summary Report - Myers 04-2J7304 Pulgas Creek Bridge (DB22377)xlsx1257.99 KB11/29/20232023-09-11-95-5   Info
Cordilleras_Creek_Bridge_09-15-2023_[Concrete]pdf3820.51 KB11/29/20232023-09-11-95-5   Info

Test was verified on 11/29/2023