Summary for Test 2023-10-11-102-4
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 994615 DEA: 112N1644 EFIS: 1122000151 |
---|---|
DIST-CO-RTE-PM | 11-IMP-8-R3.7/R48.0 |
Award Date | 05/19/2023 |
Closeout Date | 06/11/2024 |
Work Description | MICROSURFACING, COLD PLANE, RHMA, PAVEMENT MARKING, & CENSUS SYSTEMS. |
Location Description | IMPERIAL COUNTY AT VARIOUS LOCATIONS FROM 0.7 MILE EAST OF MOUNTAIN SPRINGS ROAD UNDERCROSSING TO 0.2 MILE EAST OF ROUTE 7/8 SEPARATION |
QA Service Level | 1 (Verified on 06/04/2024) |
Sample Information
Sample Taken Date | 10/11/2023 | Sample Unique Key | 102 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/13/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" RHMA-G |
The quantity of what the sample constitutes | 4 boxes 4 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 9815-PSU | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 2 | HMA Mix Number | 1 |
Test Details
DIME Sample ID: 2023-10-11-102
DIME Test ID: 2023-10-11-102-4
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-12-07
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 11/29/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7477.1 grams
Mass of oven-dry sample in air for Sample 1: 1558.4 grams
Mass of container filled with the sample and water for Sample 1: 8389.5 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.412
Theoretical maximum density at 25°C (77°F): 150.1 lb/ft^3
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/7/2023 ✔