Summary for Test 2023-10-09-84-5
Test performed: AASHTO T209-22Project Information
Project Identifiers | Project ID: 994803 DEA: 043J0704 EFIS: 0415000077 |
---|---|
DIST-CO-RTE-PM | 04-CC-80-10.1/13.5 |
Award Date | 03/10/2023 |
Closeout Date | Not set |
Work Description | Remove PCC and AC, place PCP and AC Resurfacing. |
Location Description | Construction on State Highway in Contra Costa County in Hercules and Crockett from Route 80/4 separation to 0.1 mile west of Crockett Viaduct. |
QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
Sample Taken Date | 10/09/2023 | Sample Unique Key | 84 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/16/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH HMA-SP Type A |
The quantity of what the sample constitutes | Production Start-Up | From where was the sample collected | Source |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | County Asphalt Batch Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | L230620 |
Test Details
DIME Sample ID: 2023-10-09-84
DIME Test ID: 2023-10-09-84-5
Testing Lab: CT D04 - Richmond Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-11-28
Test Results
Number of Samples: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 10/16/2023
Specific Gravity for Sample 1: 2.615
Specific Gravity for Sample 2: 2.615
Average Specific Gravity: 2.615
Theoretical maximum density at 25°C (77°F): 2 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Production Start-Up
County Asphalt Batch Plant
Theoretical Maximum Density = 2.600
Test was verified on 11/28/2023 ✔