Summary for Test 2023-11-16-5-1

Test performed: ASTM A416-18

Project Information

Project IdentifiersProject ID: 213750
DEA: 120K0224
EFIS: 1214000097
DIST-CO-RTE-PM12-ORA-5-14.5/17.1
Award Date03/05/2019
Closeout Date03/13/2025
Work DescriptionSouth County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS.
Location DescriptionORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING
QA Service Level1 (Verified on 04/15/2019)

Sample Information

Sample Taken Date11/16/2023 Sample Unique Key5
Date that the sample was received by the laboratory/organization performing the testing11/17/2023 Sample typeQuality Assurance
A brief description of the sample.6 PT Strand The quantity of what the sample constitutes1 coil
From where was the sample collectedFabricator First name of sampler or witnessed byHenry
Last name of sampler or witnessed byArredondo Title of samplerCaltrans QA Mets Inspector
Telephone number of sampler5623329603 Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameDywidag Systems International
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) FormL166-123-23
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeSMTL TM4 - Prestressing Strand Comments
Reel/Coil/Pack Number(s)S336583-4 Number of Coils
Group Number Strand Diameter.6 in
Grade270 Strand SpecificationASTM A 416
Heat Number(s)S0569223 Mfg. Lot Number(s)(Pack No. S336583-4)
Manufacturer(s)Sumiden Wire

Test Details

DIME Sample ID: 2023-11-16-5
DIME Test ID: 2023-11-16-5-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-18: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2023-11-27

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: AAuvinen
Date of test: 11/27/2023
UTM: 120kip
Temperature: 72 f
Extensometers: E88766
NumHeat NumberCoilArea (sqin)Peak Load (lbf)Load at EUL (lbf)Chord Modulus (Msi)Elongation (in)Tested By
1S0569223S336583-40.2166063454874.528.22.06AAuvinen

General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 11/27/2023 ✔