Summary for Test 2023-10-14-11-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 993121
DEA: 032H62U4
EFIS: 0319000021
DIST-CO-RTE-PM03-NEV-20-25.6/39.8
Award Date02/08/2022
Closeout DateNot set
Work DescriptionROADWAY EXCAVATION, HMA (TYPE A) WITH CLASS 2 AB, RCB CULVERT AND RCP.
Location DescriptionNEVADA COUNTY NEAR OMEGA AT VARIOUS LOCATIONS FROM 0.2 MILE WEST OF CONSERVATION ROAD (WASHINGTON RIDGE ROAD) TO 1.2 MILES WEST OF ZEIBRIGHT ROAD
QA Service Level1 (Verified on 07/26/2021)

Sample Information

Sample Taken Date10/14/2023 Sample Unique Key11
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/19/2023
Sample typeQuality Assurance A brief description of the sample3/4" HMA
The quantity of what the sample constitutes2 Oil Cans From where was the sample collectedManufacturer
First name of sampler or witnessed bySergio Last name of sampler or witnessed byTostado
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID2023-10-14-10
The fabricator/manufacturer/facility nameGranite Bradshaw Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure nameSAC-HWY20 OMEGA CRVE REALIGN

Material Information

Material TypeAsphalt Binder Performance GradePG 58-22
Modified Lot number4
Sublot number12 Tank number
Time of sample HMA Supplier100264-Bradshaw HMA plant
Certified Asphalt SupplierPacific Northwest Oil - Stockton CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-10-14-11
DIME Test ID: 2023-10-14-11-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-11-21

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 11/21/2023
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 42.009 kPa
Phase Angle (δ) (for the 10 cycles): 46.4 degree
Complex Modulus (G*) (for the 10 measurements): 4179.788 kPa
Test Temperature (Specimen 1): 22.0 C
(G*) x sin(δ)=: 3027 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 11/21/2023