Summary for Test 2023-10-27-72-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993804 DEA: 043J0624 EFIS: 0419000534 |
---|---|
DIST-CO-RTE-PM | 04-SM-101-16.5/23.0 |
Award Date | 08/24/2022 |
Closeout Date | 04/10/2024 |
Work Description | COLD PLANE AND PLACE HMA, REPLACE GUARDRAIL AND CURB RAMPS. |
Location Description | SAN MATEO COUNTY AT VARIOUS LOCATION FROM BROADWAY OVERCROSSING TO 0.2 MILE NORTH OF OYSTER POINT BOULEVARD OVERCROSSING |
QA Service Level | 1 (Verified on 05/19/2022) |
Sample Information
Sample Taken Date | 10/27/2023 | Sample Unique Key | 72 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/30/2023 |
Sample type | Production Start-Up | A brief description of the sample | 1/2" Open Grade PG 64-16 |
The quantity of what the sample constitutes | 750 Tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | LEONARDO | Last name of sampler or witnessed by | MENDOZA |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Vulcan Materials - Pleasanton | Transportation Laboratory (TL) Number | C666437 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | OGFC |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 1 | HMA Mix Number | D04 OGFC 22 001 |
Test Details
DIME Sample ID: 2023-10-27-72
DIME Test ID: 2023-10-27-72-1
Testing Lab: CT D04 - Hayward Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-22
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Leonardo Mendoza
Date of test: 11/06/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3246.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 4801.8 g
Mass of HMA Sample prior to ignition: 1554.9 g
Mass Loss: 138.2 g
Mass of aggregate remaining after ignition: 1416.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.97 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.20 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.72 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/22/2023 ✔