Summary for Test 2023-11-07-5-2
Test performed: ASTM F606-21Project Information
| Project Identifiers | Project ID: 215620 DEA: 01436404 EFIS: 0100000193 |
|---|---|
| DIST-CO-RTE-PM | 01-DN-101-35.8/36.5 |
| Award Date | 07/11/2022 |
| Closeout Date | Not set |
| Work Description | Dr. Fine Bridge Replacement |
| Location Description | DR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER. |
| QA Service Level | 1 (Verified on 03/26/2021) |
Sample Information
| Sample Taken Date | 11/07/2023 | Sample Unique Key | 5 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 11/15/2023 | Sample type | Verification |
| A brief description of the sample | AB549A SHT Brace Bolt | The quantity of what the sample constitutes | 1194 |
| From where was the sample collected | Fabricator | First name of sampler or witnessed by | Halim Kerim |
| Last name of sampler or witnessed by | Bas | Title of sampler | Inspector |
| Telephone number of sampler | 6463798761 | Laboratory sample identification | |
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Acrow Bridge | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | AB549A | |
| Washer Mfg. Lot Number(s) | AB549A | Bolt Specification | ASTM A325 |
| Bolt Length(s) | Nut Specification | ASTM A563 | |
| Washer Specification | ASTM F436 | Finish | |
| Diameter/Size | Bolt Mfg. Lot Number | AB549A | |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) | Bolt Mill Supplier | Not set | |
| Nut Mill Supplier | Not set | Washer Mill Supplier | Not set |
Test Details
DIME Sample ID: 2023-11-07-5
DIME Test ID: 2023-11-07-5-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-12-06
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 11/20/2023
UTM: 450kip
Temperature: 72 f
| Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
|---|---|---|---|---|---|---|---|
| 1 | 1B | 98339 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 12/6/2023 ✔