Summary for Test 2023-09-28-53-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 995198
DEA: 072XC404
EFIS: 0723000083
DIST-CO-RTE-PM07-LA-101-9.609999999999999/9.609999999999999
Award Date01/12/2023
Closeout Date08/21/2025
Work DescriptionNot set
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date09/28/2023 Sample Unique Key53
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/04/2023
Sample typeProduction Start-Up A brief description of the sample3/4" RHMA-G-SP 0.5% LAS
The quantity of what the sample constitutes20 BOXES OF HMA From where was the sample collectedManufacturer
First name of sampler or witnessed byEsteban Last name of sampler or witnessed bySalagado
Title of sampler Telephone number of sampler
Laboratory sample identification0506G-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Sun Valley - Big Rock Creek Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number226108 SVA3 LTR
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-09-28-53
DIME Test ID: 2023-09-28-53-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-17

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 10/07/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2117.0 g
Mass Loss: 161.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.21 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.07 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.35 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/17/2023