Summary for Test 2023-09-28-53-4
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 995198 DEA: 072XC404 EFIS: 0723000083 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-101-9.609999999999999/9.609999999999999 |
| Award Date | 01/12/2023 |
| Closeout Date | 08/21/2025 |
| Work Description | Not set |
| Location Description | Not set |
| QA Service Level | NOT VERIFIED |
Sample Information
| Sample Taken Date | 09/28/2023 | Sample Unique Key | 53 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/04/2023 |
| Sample type | Production Start-Up | A brief description of the sample | 3/4" RHMA-G-SP 0.5% LAS |
| The quantity of what the sample constitutes | 20 BOXES OF HMA | From where was the sample collected | Manufacturer |
| First name of sampler or witnessed by | Esteban | Last name of sampler or witnessed by | Salagado |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | 0506G-23 | Linked DIME Sample ID | |
| The fabricator/manufacturer/facility name | Vulcan Sun Valley - Big Rock Creek | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 226108 SVA3 LTR | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-09-28-53
DIME Test ID: 2023-09-28-53-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-17
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 10/07/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2117.0 g
Mass Loss: 161.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.21 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.07 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.35 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/17/2023 ✔