Summary for Test 2023-09-01-102-2

Test performed: CTM 557-June 2020

Project Information

Project IdentifiersProject ID: 214336
DEA: 07302404
EFIS: 0713000488
DIST-CO-RTE-PM07-VEN-101-37/40
Award Date11/17/2020
Closeout Date09/24/2024
Work DescriptionPADRE JUAN REHAB
Location DescriptionVEN 101
QA Service Level1 (Verified on 02/26/2021)

Sample Information

Sample Taken Date09/01/2023 Sample Unique Key102
Date that the sample was received by the laboratory/organization performing the testing09/01/2023 Sample typeQuality Assurance
A brief description of the sampleLCB The quantity of what the sample constitutes10 CY
From where was the sample collectedJob Site First name of sampler or witnessed byAleksey
Last name of sampler or witnessed bySouglobov Title of sampler
Telephone number of sampler Laboratory sample identification23-1337
Linked DIME Sample ID The fabricator/manufacturer/facility nameN/A
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberG3-21-PCC-351
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected120
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-09-01-102
DIME Test ID: 2023-09-01-102-2
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 557-June 2020: Method of Test for Temperature of Freshly Mixed Hydraulic Cement Concrete
Test Release Date: 2023-11-16

Test Results


Input Type: Measured
Tester's full name: Aleksey Souglobov
Date of test: 09/01/2023
Temperature: 80 F
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/16/2023 ✔