Summary for Test 2023-11-15-6-2
Test performed: AASHTO T209-22
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
Award Date | 04/23/2021 |
Closeout Date | Not set |
Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 11/15/2023 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/15/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA-A 15%RAP PG64-10 |
The quantity of what the sample constitutes | L5SL27 750tons | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Doug | Last name of sampler or witnessed by | Ruff |
Title of sampler | Consultant Tester | Telephone number of sampler | 5596470032 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Porterville Asphalt & Rock PAI | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | NB TUL 99 N of Ave 264 Tagus |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 5 |
Sublot number | 27 | HMA Mix Number |
Test Details
DIME Sample ID: 2023-11-15-6
DIME Test ID: 2023-11-15-6-2
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-11-16
Test Results
Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: James Watson
Date of test: 11/16/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7317.7 grams
Mass of oven-dry sample in air for Sample 1: 2510.5 grams
Mass of container filled with the sample and water for Sample 1: 8962.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.899
Theoretical maximum density at 25°C (77°F): 2891 kg/m^3
General comments (publicly viewable) (Max 1000 characters):
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-360244_37043_231115_L5SL27_T209 | 40.80 KB | 11/16/2023 | 2023-11-15-6-2 | Info |
Test was verified on 11/16/2023 ✔
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.