Summary for Test 2017-03-22-6-1
Test performed: CTM 670-December 2013Project Information
| Project Identifiers | Project ID: 3951 DEA: 07202114 EFIS: 0700020869 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-710-17.2/26.4 |
| Award Date | 04/04/2012 |
| Closeout Date | 06/16/2021 |
| Work Description | PAVE ROADWAY WITH LONG LIFE PAVEMENT AND WIDEN ROADWAY AND BRIDGES |
| Location Description | LOS ANGELES COUNTY ON ROUTE 710 AT VARIOUS LOCATIONS FROM LOS ANGELES RIVER BRIDGE TO RAMONA BOULEVARD UNDERCROSSING |
| QA Service Level | 1 (Verified on 11/27/2012) |
Sample Information
| Sample Taken Date | 03/22/2017 | Sample Unique Key | 6 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/04/2017 |
| Sample type | Quality Assurance | A brief description of the sample | Barsplice Doublr Barrel Zap Screwlok Coupler |
| The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Pedro | Last name of sampler or witnessed by | Labrada |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Barsplice, CMC Rebar | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | N/A | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM5 - Couplers | Production or Authorization Testing | Production Testing |
|---|---|---|---|
| Service or Ultimate | Service | Material Standard Code | ASTM A706 |
| Material Grade | 60 | Rebar Manufacturer | CMC Rebar |
| Coupler Manufacturer | BarSplice | Intermediate Assembler or Fabricator | Unknown |
| Rebar Size | #6 | Coupler Model | Barsplice Double Barrel Zap ScrewLok |
| Coating Standards | Uncoated | Shape of Rebar | Straight |
| Rebar Hoop Diameter | Unknown | Rebar Hoop Fabricator | Unknown |
| Coupler Component Heat/Lot Number(s) | 4136 | Rebar Heat Number(s) | 4062265 |
| Rebar Size 2 | Not set | Coupler Unique ID | Not set |
Test Details
DIME Sample ID: 2017-03-22-6
DIME Test ID: 2017-03-22-6-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-04-12
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 04/05/2017
UTM: 400KIP
Temperature: 72 F
| Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
|---|---|---|---|---|---|---|---|---|
| 1 | 1 | 1 | #6/19mm | 0.44 | 42020 | 95500 | Service Splice | Fred |
General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 4/5/2017 ✔