Summary for Test 2023-11-16-3-1
Test performed: CTM 231-March 2013Project Information
Project Identifiers | Project ID: 215425 DEA: 06360244 EFIS: 0613000005 |
---|---|
DIST-CO-RTE-PM | 06-TUL-99-30.6/35.2 |
Award Date | 04/23/2021 |
Closeout Date | Not set |
Work Description | Widen Freeway & Bridge Construction (Concrete Bridge) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/01/2021) |
Sample Information
Sample Taken Date | 11/16/2023 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/16/2023 |
Sample type | Quality Assurance | A brief description of the sample | Class 2 AB |
The quantity of what the sample constitutes | 2000 sq ft per CTM 231 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Doug | Last name of sampler or witnessed by | Ruff |
Title of sampler | Materials Tester | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Jobsite | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | |
---|---|---|---|
The fabricator/manufacturer designation for the sample | A detailed description of where the material sample was collected | Test holes at jobsite | |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2023-11-16-3
DIME Test ID: 2023-11-16-3-1
Testing Lab: CT D06 - Bakersfield Field Laboratory
Test Method: CTM 231-March 2013: Method of Test for Relative Compaction of Untreated and Treated Soils and Aggregates Using Nuclear Gages
Test Release Date: 2023-11-16
Test Results
Method Type:: Standard Count
Number of Tests:: 5
Common Test Maximum Used:: Yes
Input Type: Measured
Tester's full name: Doug Ruff
Date of test: 11/16/2023
Gage No.: 30695
Test No.: 550
Nuclear By: doug Ruff
Non-Bias Plan No.: 7 odd
Depth: 4
Material No.: no data
Material Type: Class 2 AB recycled
Impact By: Doug Ruff
Standard Count Density: 1779 g/cc
Count or Density 1: 1812 g/cc
Count or Density 2: 1909 g/cc
Count or Density 3: 1926 g/cc
Count or Density 4: 1736 g/cc
Count or Density 5: 1900 g/cc
Standard Count Moisture: 657 g/cc
Moisture Count 1: 133 g/cc
Moisture Count 2: 145 g/cc
Moisture Count 3: 126 g/cc
Moisture Count 4: 147 g/cc
Moisture Count 5: 137 g/cc
Density: 2.11
Moisture: 0.17
Sum of Count or Density: 9283.00 g/cc
Average of Count or Density: 1857.00 g/cc
Sum of Moisture Count: 688.00 g/cc
Average of Moisture Count: 138.00 g/cc
Count Ratio Density: 1.04
Count Ratio Moisture: 0.21
Calculated Percent Relative Compaction: 92.5 %
Reported Percent Relative Compaction: 93 %
General comments (publicly viewable) (Max 1000 characters): Sta 39+50 to 44+00 width: 60ft elevation: 1.20ft BFG
Test File Attachments
File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
---|---|---|---|---|---|
06-360244_37000_231116_550to552 | 713.75 KB | 11/16/2023 | 2023-11-16-3-1 | Info |
Test was verified on 11/16/2023 ✔