Summary for Test 2023-10-27-32-3

Test performed: AASHTO T315-22

Project Information

Project IdentifiersProject ID: 994534
DEA: 010H1604
EFIS: 0117000117
DIST-CO-RTE-PM01-MEN-101-R33.7/R43.2
Award Date05/04/2023
Closeout Date10/26/2026
Work DescriptionREPLACE AC SURFACING, PLACE HMA-A, RHMA-G & CONCRETE BARRIER.
Location DescriptionMENDOCINO COUNTY NEAR WILLITS FROM 1.1 MILES NORTH OF WEST ROAD OVERCROSSING TO 0.6 MILE SOUTH OF HAEHL CREEK BRIDGE
QA Service Level1 (Verified on 04/25/2023)

Sample Information

Sample Taken Date10/27/2023 Sample Unique Key32
Date that the sample was received by the laboratory/organization performing the testing10/31/2023 Sample typeDepartment Acceptance
A brief description of the sample pg 64-16 The quantity of what the sample constitutes1 of 1 can
From where was the sample collectedSource First name of sampler or witnessed byriley
Last name of sampler or witnessed bymelvin Title of samplerConsultant
Telephone number of sampler Laboratory sample identification23-317
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite Ukiah
Transportation Laboratory (TL) Number033186 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number2
Sublot number5 Tank number50 tons
Time of sample HMA Supplier
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number
HMA TypeNot set HMA Supplier Mix ID NumberNot set

Test Details

DIME Sample ID: 2023-10-27-32
DIME Test ID: 2023-10-27-32-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-11-15

Test Results


Phase: PAV residue
Input Type: Measured
Tester's full name: Karen Sawyer
Date of test: 11/15/2023
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 35.801 kPa
Phase Angle (δ) (for the 10 cycles): 49.7 degree
Complex Modulus (G*) (for the 10 measurements): 3562.167 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 2717 kPa
General comments (publicly viewable) (Max 1000 characters): PAV

Test was verified on 11/15/2023 ✔