Summary for Test 2023-06-16-72-1

Test performed: ASTM C39-18

Project Information

Project IdentifiersProject ID: 993815
DEA: 081C0814
EFIS: 0816000086
DIST-CO-RTE-PM08-RIV-10-R60.7/R74.3
Award Date03/28/2022
Closeout Date01/21/2026
Work DescriptionI-10 PAVEMENT REHABILITATION (SEGMENT 1) PROJECT
Location DescriptionCoachella
QA Service Level1 (Verified on 05/03/2022)

Sample Information

Sample Taken Date06/16/2023 Sample Unique Key72
Date that the sample was received by the laboratory/organization performing the testing06/17/2023 Sample typeQuality Control
A brief description of the samplestructural concrete The quantity of what the sample constitutes2 cylinders
From where was the sample collectedJob Site First name of sampler or witnessed byKristian
Last name of sampler or witnessed byLopez Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameGranite-Indio
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberCT590F25
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected821063
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedDS -57 Box Culvert ( Invert ) Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-06-16-72
DIME Test ID: 2023-06-16-72-1
Testing Lab: Sequoia Consultants
Test Method: ASTM C39-18: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-11-14

Test Results


Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Gavin Hernandez
Date of test: 07/14/2023
Average diameter of cylinder 1: 6.01 in
Average diameter of cylinder 2: 6.01 in
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Maximum load on cylinder 1: 135870 lb
Maximum load on cylinder 2: 134050 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 28.37 in^2
Cross sectional area of cylinder 2: 28.37 in^2
Compressive strength (to nearest 10 psi): 4760 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/14/2023 ✔