Summary for Test 2023-07-21-99-1
Test performed: CTM 521-June 2012Project Information
| Project Identifiers | Project ID: 209698 DEA: 072332E4 EFIS: 0700000391 COOP: 0705187 |
|---|---|
| DIST-CO-RTE-PM | 07-LA-I-5-45.4/54 |
| Award Date | 07/01/2021 |
| Closeout Date | Not set |
| Work Description | Addition of 14 miles of HOV lanes in both directions would extend existing carpool lanes on the I- 5 in San Fernando Valley to Santa Clarita Valley |
| Location Description | The I-5 North Capacity Enhancements Project focuses on improvements to the I-5 freeway from cities of Santa Clarita and Castaic, beginning at the SR-14 interchange to Parker Rd. |
| QA Service Level | 2 (Verified on 02/03/2021) |
Sample Information
| Sample Taken Date | 07/21/2023 | Sample Unique Key | 99 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/22/2023 |
| Sample type | Quality Control | A brief description of the sample | Structural Concrete |
| The quantity of what the sample constitutes | 2 cylinders | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Alphonso | Last name of sampler or witnessed by | Morris |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | National RM | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | S63C451T1 |
|---|---|---|---|
| The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 280847 | |
| Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
| A detailed description of where the material sample was collected | RW 2708 wall station 10+93 - 11+92 | Where the material sample would have been placed if not sampled | |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-07-21-99
DIME Test ID: 2023-07-21-99-1
Testing Lab: Sequoia Consultants
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-11-13
Test Results
Number of specimens: 2
Input Type: Calculated
Tester's full name: Carlos Nunez
Date of test: 09/01/2023
Correction factor: 1
Cylinder Age: 42 days
Break Description of Cylinder 1 (if not 'cone'): 6
Break Description of Cylinder 2 (if not 'cone'): 5
Average Compressive Strength (to nearest 10): 3720 lb/in^2
Compressive Strength of Cylinder 1: 3688 lb/in^2
Compressive Strength of Cylinder 2: 3754 lb/in^2
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/13/2023 ✔