Summary for Test 2023-10-27-60-3
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994812 DEA: 042K7204 EFIS: 0417000014 |
|---|---|
| DIST-CO-RTE-PM | 04-CC-4-R14.3/24.3 |
| Award Date | 03/23/2023 |
| Closeout Date | 10/06/2025 |
| Work Description | Pvmt rehabilitation, slab repl, ADA curb ramp and install guardrail. |
| Location Description | On state highway in Contra Costa County in and near Concord and Pittsburg from 0.3 miles east of Peralta Road Undercrossing to Loveridge Road Overcrossing. |
| QA Service Level | 1 (Verified on 05/10/2023) |
Sample Information
| Sample Taken Date | 10/27/2023 | Sample Unique Key | 60 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/02/2023 |
| Sample type | Quality Assurance | A brief description of the sample | 3/4-INCH HMA Type A |
| The quantity of what the sample constitutes | Sample 3 of the day | From where was the sample collected | Source |
| First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
| Title of sampler | Telephone number of sampler | 7072999133 | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Granite Pleasanton Drier Drum Plant | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | |
| Sublot number | HMA Mix Number | 3923 | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-10-27-60
DIME Test ID: 2023-10-27-60-3
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-13
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 11/02/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2342.5 g
Mass Loss: 150.2 g
Correction Factor (Percent by mass of HMA Specimen): 5.38 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.12 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 0.92 %
General comments (publicly viewable) (Max 1000 characters): Granite Pleasanton Drier Drum Plant
Sample 3 of the day
Test was verified on 11/13/2023 ✔