Summary for Test 2023-10-18-8-7
Test performed: AASHTO T315-22Project Information
| Project Identifiers | Project ID: 993169 DEA: 050A0904 EFIS: 0513000028 |
|---|---|
| DIST-CO-RTE-PM | 05-MON-156-R1.4/R2.0 |
| Award Date | 12/14/2021 |
| Closeout Date | 07/31/2024 |
| Work Description | WIDEN REINFORCED STRUCTURAL CONCRETE BRIDGE & REPLACE BRIDGE RAILING. |
| Location Description | MONTEREY COUNTY IN AND NEAR CASTROVILLE FROM 0.3 MILE EAST OF ROUTE 156/183 SEPARATION TO 0.2 MILE EAST OF CASTROVILLE BOULEVARD |
| QA Service Level | 1 (Verified on 08/17/2021) |
Sample Information
| Sample Taken Date | 10/18/2023 | Sample Unique Key | 8 |
|---|---|---|---|
| Date that the sample was received by the laboratory/organization performing the testing | 10/18/2023 | Sample type | Quality Assurance |
| A brief description of the sample | PG64-10 SJR | The quantity of what the sample constitutes | 1 Can |
| From where was the sample collected | Other | First name of sampler or witnessed by | Jerrod |
| Last name of sampler or witnessed by | Naval | Title of sampler | QC |
| Telephone number of sampler | Laboratory sample identification | ||
| Linked DIME Sample ID | The fabricator/manufacturer/facility name | Graniterock Aromas Drum Plant | |
| Transportation Laboratory (TL) Number | Inspector Lot Number from the Transportation Laboratory (TL) Form | ||
| Structure unique identifier | Structure name | ||
| Bid Item | Not set |
Material Information
| Material Type | Asphalt Binder | Performance Grade | PG 64-10 |
|---|---|---|---|
| Modified | No | Lot number | 1 |
| Sublot number | 1 | Tank number | |
| Time of sample | HMA Supplier | Granite Salinas Batch Plant | |
| Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
| Multigrade Type | Asphalt Binder Mix Number | 937 | |
| HMA Type | Not set | HMA Supplier Mix ID Number | Not set |
Test Details
DIME Sample ID: 2023-10-18-8
DIME Test ID: 2023-10-18-8-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-11-15
Test Results
Phase: RTFO residue
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 11/09/2023
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 10.00 %
Stress Amplitude: 0.270 kPa
Phase Angle (δ) (for the 10 cycles): 88.9 degree
Complex Modulus (G*) (for the 10 measurements): 2.685 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 2.69 kPa
General comments (publicly viewable) (Max 1000 characters): rtfo
Test was verified on 11/15/2023 ✔