Summary for Test 2017-03-23-5-53
Test performed: ASTM B499-14Project Information
| Project Identifiers | Project ID: 210097 DEA: 100L9704 EFIS: 1012000053 |
|---|---|
| DIST-CO-RTE-PM | 10-TUO-120-R19.5/R20.0 |
| Award Date | 02/22/2016 |
| Closeout Date | 10/09/2018 |
| Work Description | REPLACE DECK AND RETROFIT BRIDGE. |
| Location Description | IN TUOLUMNE COUNTY ON STATE ROUTE 120 FROM 7.6 MILES EAST OF YOSEMITEJUNCTION TO 4.8 MILES WEST OF THE TOWN OF MOCCASIN AT TUOLUMNE RIVER/DON PEDRO RESERVOIR (JAMES E. |
| QA Service Level | 1 (Verified on 12/19/2014) |
Sample Information
| Sample Taken Date | 03/23/2017 | Sample Unique Key | 5 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/27/2017 |
| Sample type | Quality Assurance | A brief description of the sample | A325 HDG |
| The quantity of what the sample constitutes | 99 | From where was the sample collected | Distributor |
| First name of sampler or witnessed by | Scott | Last name of sampler or witnessed by | Leavitt |
| Title of sampler | Unknown | Telephone number of sampler | Unknown |
| Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
| The fabricator/manufacturer/facility name | Universal Industrial Sales | Transportation Laboratory (TL) Number | Unknown |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | S2808217 | Structure unique identifier | Not set |
| Structure name | Not set | Bid Item | Not set |
Material Information
| Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
|---|---|---|---|
| Heat Number(s) | Nut Mfg. Lot Number(s) | 15-40-006 15-01-005 | |
| Washer Mfg. Lot Number(s) | D1782 D2656 | Bolt Specification | A325 |
| Bolt Length(s) | 5.5" 4.5" 4" | Nut Specification | A563-DH |
| Washer Specification | F436 | Finish | HDG |
| Diameter/Size | 0.75" 0.5" | Bolt Mfg. Lot Number | BG0229 BG0609 BG0590 G8245 G8533 |
| Rocap Test Requirement(s) | Lubricant Requirements(s) | ||
| Washer Inner Diameter(s) |
Test Details
DIME Sample ID: 2017-03-23-5
DIME Test ID: 2017-03-23-5-53
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2017-04-11
Test Results
Input Type: Calculated
Tester's full name: Arnold Viken
Date of test: 04/03/2017
Sample No.: 6C
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: G8245
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: A325 BBC
Size: 0.5 in
Bolt Length: 4 in
Measurement Average: 4.91 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 4/4/2017 ✔