Summary for Test 2023-11-07-48-2
Test performed: AASHTO T308-10Project Information
| Project Identifiers | Project ID: 994729 DEA: 034H88U4 EFIS: 0323000024 |
|---|---|
| DIST-CO-RTE-PM | 03-BUT-32-0.3/5.0 |
| Award Date | 06/30/2023 |
| Closeout Date | 04/01/2025 |
| Work Description | INSTALL LIGHTING, WIDEN SHLD, UPGRADE END TREATMENTS, EXTEND CULVERTS. |
| Location Description | BUTTE COUNTY NEAR CHICO FROM 0.3 MILE EAST OF BUTTE COUNTY LINE TO MUIR AVENUE |
| QA Service Level | 1 (Verified on 05/15/2023) |
Sample Information
| Sample Taken Date | 11/07/2023 | Sample Unique Key | 48 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/08/2023 |
| Sample type | Quality Assurance | A brief description of the sample | Boxes of Mix |
| The quantity of what the sample constitutes | 3/4" HMA-A | From where was the sample collected | Job Site |
| First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeehan |
| Title of sampler | Telephone number of sampler | ||
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | KRC Orland | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Bid Item | Not set |
Material Information
| Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
|---|---|---|---|
| HMA Grading | 3/4 inch | Lot number | 1 |
| Sublot number | 1 | HMA Mix Number | |
| Binder content (%) | Not set | Virgin binder PG | Not set |
| Design binder PG | Not set | Binder Supplier | Not set |
| RAP content (%) | Not set | WMA Additives | Not set |
| Antistrip type | Not set |
Test Details
DIME Sample ID: 2023-11-07-48
DIME Test ID: 2023-11-07-48-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Josh Wilson
Date of test: 11/08/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2130.7 g
Mass Loss: 122.4 g
Correction Factor (Percent by mass of HMA Specimen): 0.79 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.95 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/8/2023 ✔