Summary for Test 2023-10-10-76-1
Test performed: CTM 521-June 2020Project Information
| Project Identifiers | Project ID: 994443 DEA: 053307C4 EFIS: 0514000028 |
|---|---|
| DIST-CO-RTE-PM | 05-SLO-41,46-44.5/45.3,54.0/57.8 |
| Award Date | 02/27/2023 |
| Closeout Date | Not set |
| Work Description | Wye Segment - Route 41/46 Separation |
| Location Description | Not set |
| QA Service Level | 1 (Verified on 12/16/2022) |
Sample Information
| Sample Taken Date | 10/10/2023 | Sample Unique Key | 76 |
|---|---|---|---|
| Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/11/2023 |
| Sample type | Department Acceptance | A brief description of the sample | 4x8 Concrete Cylinders |
| The quantity of what the sample constitutes | Trial Batch - 3F36L005 | From where was the sample collected | Fabricator |
| First name of sampler or witnessed by | Kyle | Last name of sampler or witnessed by | Engen |
| Title of sampler | TET | Telephone number of sampler | |
| Laboratory sample identification | Linked DIME Sample ID | ||
| The fabricator/manufacturer/facility name | Holliday Rock | Transportation Laboratory (TL) Number | |
| Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
| Structure name | Trial Batch-Structures | Bid Item | Not set |
Material Information
| Material Type | Concrete | The concrete mix design number | 3F36L005 |
|---|---|---|---|
| The truck number from where the sample was collected | 794 | The batch plant ticket number from where the sample was collected | 20100590 |
| Concrete batch plant | Holliday Rock Company | The fabricator/manufacturer designation for the sample | |
| A detailed description of where the material sample was collected | Mix Truck | Where the material sample would have been placed if not sampled | Trial Batch |
| From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-10-10-76
DIME Test ID: 2023-10-10-76-1
Testing Lab: CT D05 - Whitley Gardens Field Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-11-07
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Kyle Engen
Date of test: 11/07/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.05 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 66547 lb
Maximum load on cylinder 2: 55711 lb
Maximum load on cylinder 3: 61611 lb
Type of fracture pattern of cylinder 1: 4
Type of fracture pattern of cylinder 2: 4
Type of fracture pattern of cylinder 3: 4
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.88 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 5166.7 psi
Compressive strength of cylinder 2: 4432.1 psi
Compressive strength of cylinder 3: 4901.4 psi
Compressive strength (to nearest 10 psi): 4830 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day break for Trial Batch
Test File Attachments
| File Name | Extension | File Size | Date Uploaded | Test ID | Actions |
|---|---|---|---|---|---|
| 05-3307C4_CTM 521_KEE_231010_3F36L005_Trial Batch_28 Day_3x_1 | 85.83 KB | 11/07/2023 | 2023-10-10-76-1 | Info |
Test was verified on 11/7/2023 ✔