Summary for Test 2023-07-11-73-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994785
DEA: 023H32U4
EFIS: 0221000164
DIST-CO-RTE-PM02-SIS-I5-2.5/R15.9
Award Date04/28/2023
Closeout DateNot set
Work DescriptionRoadway rehabilitation and bridge improvements along I5 in Mount Shasta
Location DescriptionSIS I5 2.5/R15.9
QA Service Level1 (Verified on 05/03/2023)

Sample Information

Sample Taken Date07/11/2023 Sample Unique Key73
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/11/2023
Sample typeProduction Start-Up A brief description of the sampleCombined RAP
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byDave and Craig "Clint" Last name of sampler or witnessed byLockett and Rogers
Title of sampler Telephone number of sampler
Laboratory sample identificationD79292B Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis – Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number036763
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name Bid ItemNot set

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceNorthstate Asphalt
Aggregate Size1/2-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2023-07-11-73
DIME Test ID: 2023-07-11-73-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-07

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 07/17/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3109.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 4693.8 g
Mass of HMA Sample prior to ignition: 1584.8 g
Mass Loss: 88.5 g
Mass of aggregate remaining after ignition: 1496.3 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.39 %
General comments (publicly viewable) (Max 1000 characters): Pbr(uncorrected)=5.39

Test was verified on 11/7/2023