Summary for Test 2023-07-10-71-3

Test performed: CTM 212-May 2010

Project Information

Project IdentifiersProject ID: 993339
DEA: 024H9304
EFIS: 0219000027
DIST-CO-RTE-PM02-SHA-299-44.3/44.9
Award Date07/13/2022
Closeout Date04/11/2024
Work DescriptionINGOT CURVE IMPROVEMENT - CURVE IMROVEMENT
Location DescriptionIN SHASTA COUNTY NEAR INGOT FROM 2.7 MILES EAST OF SEAMANS GULCH ROAD TO 1.2 MILES WEST OF DU BOIS ROAD.
QA Service Level1 (Verified on 11/22/2021)

Sample Information

Sample Taken Date07/10/2023 Sample Unique Key71
Date that the sample was received by the laboratory/organization performing the testing07/10/2023 Sample typeDepartment Acceptance
A brief description of the sample3 bags of Shoulder Backing The quantity of what the sample constitutesEntire Project
From where was the sample collectedManufacturer First name of sampler or witnessed byCindy
Last name of sampler or witnessed byBryant Title of samplerTET
Telephone number of sampler Laboratory sample identificationD79289
Linked DIME Sample ID The fabricator/manufacturer/facility nameBear Gulch Quarry
Transportation Laboratory (TL) Number858122 Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-45-0023
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedStockpile
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-10-71
DIME Test ID: 2023-07-10-71-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 212-May 2010: Method of Test for Unit Weight of Aggregate
Test Release Date: 2023-11-06

Test Results


Input Type: Measured
Tester's full name: Dennis Hickey
Date of test: 07/19/2023
Which procedure was used to fill the measure with aggregate?: no data
Weight of water in the measure: 21.053 lbm
Water temperature: 73 deg F
Tare weight of empty measure: 12.973 lbm
Weight of measure filled with aggregate (test 1): 48.267 lbm
Weight of measure filled with aggregate (test 2): 47.495 lbm
Weight of measure filled with aggregate (test 3): 48.167 lbm
Water density: 62.28 lbf/ft^3
Factor F: 2.96 ft^-3
Net weight of aggregate in measure (test 1): 35.29 lbm
Net weight of aggregate in measure (test 2): 34.52 lbm
Net weight of aggregate in measure (test 3): 35.19 lbm
Average net weight of aggregate required to fill the measure: 35 lbm
Aggregate unit weight: 103.54 lbf/ft^3
General comments (publicly viewable) (Max 1000 characters): UW≈104pcf

Test was verified on 11/6/2023 ✔