Summary for Test 2023-10-03-85-4

Test performed: CTM 523-May 2020

Project Information

Project IdentifiersProject ID: 214337
DEA: 080E33U4
EFIS: 0817000075
DIST-CO-RTE-PM08-SBD-115-R7.3/R10.0
Award Date04/26/2021
Closeout Date06/09/2025
Work DescriptionADD WB AUX & EB DECEL LANES, WIDEN I15 SW CONNECT,RAMPS/BRDG
Location DescriptionSAN BERNARDINO COUNTY IN ONTARIO FROM 0.2 MILE WEST OF CUCAMONGA CREEK BRIDGE TO MILLIKEN AVENUE
QA Service Level1 (Verified on 06/23/2021)

Sample Information

Sample Taken Date10/03/2023 Sample Unique Key85
Date that the sample was received by the laboratory/organization performing the testing10/05/2023 Sample typeDepartment Acceptance
A brief description of the sampleConcrete beams The quantity of what the sample constitutes3 Beams
From where was the sample collectedJob Site First name of sampler or witnessed byRigoberto
Last name of sampler or witnessed byArroyo Title of sampler
Telephone number of sampler Laboratory sample identification22-A1, 22-A2, 22-A3
Linked DIME Sample ID The fabricator/manufacturer/facility nameRobertson's Ready Mix - Fontana
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeConcrete The concrete mix design numberLB0608SP
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected7851824
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedback of concrete truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-10-03-85
DIME Test ID: 2023-10-03-85-4
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 523-May 2020: Method of Test for Flexural Strength of Concrete
Test Release Date: 2023-11-06

Test Results


Number of specimens: 3
Unit system used?: US Units
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: R. Jarquin / M. Landaverde
Date of test: 11/01/2023
Identification number: #22
Width of specimen: 6.0 inch
Width of specimen 2: 6.0 inch
Width of specimen 3: 6.0 inch
Depth of specimen: 6.1 inch
Depth of specimen 2: 6.2 inch
Depth of specimen 3: 6.1 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 7190 lb
Maximum load applied 2: 8245 lb
Maximum load applied 3: 7635 lb
Curing history and apparent moisture condition of the specimen: Curing Room, Moist
If specimen was capped, ground or if leather shims were used: Leather Shims
Defects in specimen: No
Age of specimen: 28 days
Age of specimen in hours: 14 hours
Modulus of rupture: 585 psi
Modulus of rupture 2: 655 psi
Modulus of rupture 3: 620 psi
Modulus of rupture average: 620 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/6/2023 ✔