Summary for Test 2023-11-02-19-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994309
DEA: 033H5404
EFIS: 0318000012
DIST-CO-RTE-PM03-BUT-70-46.0/47.0
Award Date02/10/2023
Closeout Date07/31/2026
Work DescriptionRAISE ALIGNMENT, PLACE HMA, STRUCTURAL CONCRETE & BRIDGE RAIL.
Location DescriptionBUTTE COUNTY NEAR PARADISE FROM 0.8 MILE WEST OF SHADY REST AREA TO 0.2 MILE EAST OF SHADY REST AREA
QA Service Level1 (Verified on 10/04/2022)

Sample Information

Sample Taken Date11/02/2023 Sample Unique Key19
Date that the sample was received by the laboratory/organization performing the testing11/02/2023 Sample typeQuality Assurance
A brief description of the sampleBoxes of Mix The quantity of what the sample constitutes3/4" HMA-A
From where was the sample collectedJob Site First name of sampler or witnessed byBrad
Last name of sampler or witnessed byMcKeehan Title of sampler
Telephone number of sampler Laboratory sample identification
Linked DIME Sample ID The fabricator/manufacturer/facility nameTeichert Hallwood
Transportation Laboratory (TL) Number Inspector Lot Number from the Transportation Laboratory (TL) Form
Structure unique identifier Structure name
Bid ItemNot set

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number1
Sublot number2 HMA Mix Number
Binder content (%)Not set Virgin binder PGNot set
Design binder PGNot set Binder SupplierNot set
RAP content (%)Not set WMA AdditivesNot set
Antistrip typeNot set

Test Details

DIME Sample ID: 2023-11-02-19
DIME Test ID: 2023-11-02-19-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-03

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Josh Wilson
Date of test: 11/03/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2114.7 g
Mass Loss: 119.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.53 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.02 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.13 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/3/2023 ✔